fedi_dmri_qweights
Synopsis
Process diffusion MRI scheme and generate Siemens scanner compatible output.
Usage
fedi_dmri_qweights [-h] -i <file> -o <file> -b <int> [<int> ...] -d <file>
[--interspersed] [-n <int>] [--b0_at_beginning] [--b0_at_end]
Options
Help
-h, –help Show this help message and exit
Mandatory
-i, –unitary_scheme <file> Path to the input scheme file from http://www.emmanuelcaruyer.com/q-space-sampling.php containing unitary directions and b-values (e.g., Sample.txt)
-o, –siemens_scheme <file> Output file where directions will be saved in Siemens scanner format (*.dvs)
-b, –bvalues <int> [<int> …] List of b-values corresponding to each shell in the input scheme (e.g., 1000 2000 3000)
-d, –debug_file <file> Path to a debug file where detailed info about directions and weights will be logged
Optional
–interspersed Intersperse b=0 volumes among the directions (default: False)
-n, –num_b0_volumes <int> Number of b=0 volumes to include (only if –interspersed is used)
–b0_at_beginning Include a b=0 volume at the beginning of the acquisition
–b0_at_end Include a b=0 volume at the end of the acquisition